Summary
Compacting overhead transmision lines enables reducing space occupation for the same transmissible electric power, or increasing the transmissible power for the same space occupation.
The space occupation of overhead lines is determined by the air clearances which should :
- comply with the line caracteristics
- withstand the applied stresses
- keep within acceptable limits the phenomena which may unfavourably affect the environment
- comply with construction and operational requirements
The list of papers is available, please contact the Publications Team to select the papers you are interested in.
SECTION 1
Changes in the mechanical characteristics of the lines related to their compaction.
Tower construction, type of conductor and of bundle, earth and phase clearances, conductor
sags, span lengths, etc.. are considered
- 100-01 - Pylône Raquette - Recherche c\'esthétic1ue et de réduction d'encombrement pour un pylône d'arrêt 380kv autoporteur réalisé selon la nouvelle conception des tôles pliées à froid - P. de WECK, M. AMMANN (Suisse/Switzerland), P. FAGGIANO (Italie/Italy)
- 100-02 - Guyed circuit-type suspension tower of polymerlong-rod insulators for 1150 kV transmission Unes · E.A KHVOLES, Yu.A. BOLDIN, A.S. GA YVORONSKY, V.A. GOROSHICTNA, S.V. KRYLOV, A.G. OVSYANNICKOV, K.V. YANSHIN (URSS/USSR)
- 100-03 - Insulating suspension of conductors for compact EHV transmission lines of increased capacity - P.V. GORBUNOV, S.V. KRYLOV (URSS/ USSR)
- 100-04 - A 110 kV overhead transmission line of compact type : design, operating experience, conductor oscillation control · D.S. SA VVAITOV, V.A. SHKAPTSOV, P.A. BUSHUEV, LM. NOSOV (URSS/USSR), K.O. PAPAILIOU (Suisse/Switzerland), W.F. BÜCKNER (Allemagne/Gennany), J.C. POFFENBERGER (Etats-Unis/United States)
- 100-05 - Limits to the compacting of EHV Unes imposed by conductor movement · P. PELACCHI, R. GIGLIOLI, P. NICOLINI, P. PAOLI, B.A. CAUZILLO, D. DELL'OLIO (Italie/Italy)
- 100-06 - Uprating of transmission capacity in "great Riyadh 132 kV T/L grid system" by adopting small sag and thermal rate-op conductor · A. ICTKUCHI, R. MORIMOTO, K. MITO, Y. KIMURA, A. MIKUMO (Japon/Japan)
- 100-07 - EHV compactlines: a new solution- A. CLERICI, M. LANDONIO, L. PARIS (Italie/Italy)
- 100-08 - Application oflow-sagconductors - M. YOSHJOKA, K. MARUYAMA, T. YAMAMOTO (.lapon/ Japan)
- 100-09 - 132 kV compacting overhead transmission line - L. BURGUERA ALBIZ, A. LOPEZ SUERO, J.M. SOLA LIBERAL (Espagne/Spain)
- 100-10 - ENEL's achievements and prospects in the area of compact 380 kV lincs · F. BONI, B.A. CAUZILLO, E. FRANCO, U. ZANETTA, P. NICOLINI, P. PAOLI (Ilalie/Italy)
SECTION 2
Effect on the mechanical strenglh and performance of fines of the changes related to line compaction. Wind, galloping, ice-loading, short-circuits, etc ... are considered
- 200-01 - Galloping and compact line -J.L. LILIEN (Belgique/Belgium)
- 200-02 - Static and dynamic testing of transmission lines subjected to real wind conditions - S. HOULE, E. GHANNOUM, C. HARDY (Canada)
- 200-03 - Interphase spacers improve performance of existing EHV compact transmission Jine design . C.F. CLARK, G.A. PARKS (Etats-Unis/United States)
- 200-04 - Eletronortc Brazil-500kV and 230 kV compact lines : design and mechanical aspects -J.A.A. CASAGRANDE, F. SGANZERLA, C. MARQUES,F.L. FRANCO, D.B. GALIANO (Brasil/ Brazil)
- 200-05 - Transmission line compaction in Ontario Hydro - D.G. HAV ARD, M.S. NASHID, J.R. MEALE, S.M. FOTY (Canada)
- 200-06 - Self-supporting towers for 500 kV compact lines - J.B.G.F. da SILVA, P.R.R.L.da SILVA (Brésil/ Brazil)
- 200-07 - Experience from HV and EHV compact lines - M.COJAN (France)
- 200-08 - Interphase spacer for overhead lines -Y. MASTUZAKI, R. KIMATA, T. IKEYA (Japon/Tapan), A. BOGNAR, P. SZAPLONCZAY, M. TEGLAS (Hongrie/Hungary)
- 200-09 - Parameter sensitivity analysis ofbundlcd conductors to ice galloping-G. DIANA, F. CHELI, A. COLLINA, A. MANENTI, P. NTCOLINI, F. TA VANO (Italie/Italy)
SECTION 3
Changes in the electrical parameters of lines related to their compaction. Series and shunt
capacitance, surge impedance, maximum transmissible power, etc ... are considered
- 300-01 - Technical development of reduced line inductance for bulk power transmission - Y. TAKAGI, M.SUGIHARA, M. ADACHI (Japon/Japan)
- 300-02 - Controlled self-compensating high voltage power lines - Yu.N. ASTAKHOV, V.M. POSTOLATIY (URSS/USSR)
- 300-03 - Insulation constructions and fittings of self-compensating overhead transmission lines - S. V. KRYLOV, V.M. POSTOLATIY, L.V. TIMASHOVA (URSS/USSR)
- 300-04 - Scientific and engineering principlcs of creating compact lines with increased natural capacity - G.N. ALEXANDROV (URSS/USSR)
- 300-05 - Design features of the compact lincs with enhanced surge-impedance loading built in the USSR-G.N. ALEXANDROV, G. V. PODPORKYN, LM. NOSOV, Ye.A. KHMELNOV, A.V. GORELOV, Al. KURNOSOV (URSS/USSR)
- 300-06 - Studies of the dielectric strength of phase-toground and phase-to-phase clearances of EHV and UHV power transmission lines - Yu.M. GUTMAN, N.I. STEPINA (URSS/USSR)
- 300-07 - Eletronorte Brazil - 500 kV and 230 kV compact lines: design and electrical aspects - J.H.M. FERNANDES, J.G. TANNURI, W. SATO, N. KABA F°, J.M. ARIMORI (Brésil/Brazi/)
- 300-08 - Overhead lines with optimum conductor configuration for EHV AC transmission systems - A. CLERICI, G. VALTORTA, L. PARIS (Italie/Italy)
SECTION 4
Effect on the dielectric strength and performance of fines of the changes in conductor and tower configuration, and of the application of MOAs and polymeric insulators.
- 400-01 - Insolation optimization of a Swedish urban area line - R. ERIKSSON, P. PETTERSSON (Suède/ Sweden)
- 400-02 - Results of research on the electric strength of phase-ta-phase air gaps in compact lines at switching and lightning surge impulses - G.V. PODPORKYN, AD. SIV AYEV (URSS/USSR)
- 400-03 - Special features of lightning protection of compact EHV and UHV overhcad lines - AN. NOVIKOVA (URSS/USSR)
- 400-04 - Application of composite insulators for overhead compact lines - L. PARIS (ltalie/Italy), L. PARGAMIN, R. PARRAUD (France)
- 400-05 - Utilization of composite insulators for compacting transmission lines - G.G. KARADY, H.M. SCHNEIDER, J.F. HALL (Etats-Unis/United States)
- 400-06 - Protection of compact transmission lines wilh metal oxide arresters- J.R. RIBEIRO, S.R. LAMBERT, D.D. WILSON (Etats-Unis/United States)
- 400-07 - Compacting of high voltage transmission limas : Iaboratory investigations about the influence of the surface material on the pollution performance of insulating cross arms - G.P. FINI, A. PORRINO, R. NICOLINI, A. PIGINI, F. ZAGLJANI (Italie/Italy)
SECTION 5
Constraints to fine compaction consequent to the limitatùm of interferences as appearance, corona, RIV, RTV, audible noise, electric and magnetic fields, ion currents, etc ...
- 500-01 - Determining right-of-way power transfer capability- R.E. KENNON (Etats-Unis/United States)
- 500-02 - L'effet de couronne sur les lignes compactes - M.UNGUREANU, G. MAGUREANU, D. CRISTESCU (Roumanie/Rumania)
- 500-03 - L'état de la réalisation des lignes compactes de 400 kV en Roumanie - D. CRISTESCU, S. COATU, G. GHEORGHITA, F. VATRA (Roumanie/Rumania)
- 500-04 - The compaction of conductor-to-tower clearances on Eskom's 765 kV transmission lines - A.C. BRITTEN, D.H. CRETCHLEY, K.J. SADURSKI, B. DRUIF, H.A. ROETS (Afrique du Sud/ South Africa)
SECTION 6
Line compaction obtained by voltage upgrading of exivting lines or by converting the exivting systemv to HVDC, to hybrid solutions or to multiphase systems
- 600-01 - Six-phase power transmission: first utility application- T.F. DORAZIO,J.R. STEWART, D.D. WILSON (Etals-Unis/United States)
- 600-02 - Standardized towcrs for emergency use and compact lines in Switzerland - B. KR UMM, B. BURKHARDT, B. STAUB (Suisse/Switzerland)
- 600-03 - Hybrid transmission corridors - corona and field effects - B.A. CLAIRMONT, L.E. ZAFFANELLA, L.Z. CABEZA, G.I. STILLMAN, S. ZELINGHER (Etals-Unis/United States)
- 600-04 - Optimization of open-wire transmission - L.O. BARTHOLD (Etats-Unis/United States)
- 600-05 - Power upgrading of existing ovcrhcad transmission line corridors - A CLERTCI, L. PARIS (llalie/Italy)
SECTION 7
General discussions of actual projects of operational experience, of maintenance and of special aspects (power feeding with electrical fields, etc...). Technical and economical comparison between compact and conventional lines
- 700-01 - HV line with reduced clearances - Y.MOLLER, M. GAUDRY (France)
- 700-02 - Narrower transmission corridors for EHV and UHV lines - R. SUSENDRAN (lnde/India)
- 700-03 - Compaction of 330-750 kV overhead lines by window towers : technico-economic aspects- N .N TIKHODEEV, L.E. KUZNETSOVA, A.AZEVIN, B.M. KLEBANOV (URSS/USSR)
- 700-04 - A look at compacting transmission lines using armless construction under today's constraints T.A. PINKHAM, AC. BAKER, J.C. POHLMAN (Etats-Unis/United States)
- 700-05 - Compact 110kV overheadline - E.HOFFMANN, H.v. RHEINBABEN, R.TREBESS (Allemagne/ Germany)
- 700-06 - Viability studies ofapplicalion of compact 500 kV transmission lines on the CHESF (Brazil) systems · M.0.B.C. de MELO, V.S. ANDRADE, V.Q. DUARTE, A.P. NETO, C.M.V. TAI-JAN, D.O.C. BRASIL, W. SATO (Brésil/Brazil)
- 700-07 - Technical, economical and environmental aspects of compact overhead lines - W.F. BÜCKNER, H.J. KOGLIN, R. ZEWE, F. HIRSCH, K.-H. WECK (Allemagne/Germany)
- 700-08 - Economical and technical conditions for the introduction of compact 420kV AC and DC lines into Swedish urban arcas - A. ERIKSSON, L. SÔDERBERG, R. RURITZ, U. JONSSON (Suède/Sweden)
- 700-09 - Environmcntal considcrations in movcs towards the compaction of 11 Lo 66 kV overhead lines - F.A. AUDITORE, J.C.A. HOBBS (Afrique du Sud/South Africa)