Summary
♦ Session Delegates (Members and non-members) : access these materials for free via your Session registration account.
♦ Important note: The size of the ZIP file is very large. Make sure you have a very good Internet connection for downloading.
Contents:
Videos
General
- Opening Ceremony
- Opening Panel
- Next Generation Network forum
- Women In Energy forum (2 videos)
Study Committee B3
- GDM: Substations and electrical installations (2 videos)
- Workshop A2/A3/B3/C3/D1: Driving T&D substations and equipment towards ZERO emissions
Documents PDF
- Group Discussion Meeting: Presentations and Text versions
- General Report
- Tutorial JWG B3/A3.59: Guidelines for SF6 end of life treatment of T&D equipment (>1 kV) in substations
- Joint Workshop A2/A3/B3/C3/D1: Driving T&D substations and equipment towards zero emissions
Session Papers & Poster Presentations
- 10139 - In situ monitoring of the precision shift of capacitive voltage transformers
- 10141 - Solutions for temporarily increasing the Reliable Installation Capacity
- 10309 - Integration, Operation and Maintenance of AIS Circuit Breakers using SF6 alternatives - experience with the 3 HV main technologies
- 10322 - Next Generation Distribution Center in a Box (DCIAB)
- 10337 - Small Modular Reactor and Hydrogen Production: "Impacts on Substation Design"
- 10338 - Conceptual Design of Semi-submersible Floating Offshore HVAC Substation Solution
- 10339 - Seismic Resilience of Interconnected Substation Equipment: Lessons Learned from a Comprehensive Test and Modelling Program
- 10340 - Condition & Risk Assessment: Plans and Reality
- 10341 - System Approach to Evaluation and Deployment of Substation Robotics
- 10342 - Evaluating and Comparing Substation Threat Mitigation Tactics: Substation Improvements for a More Resilient Power Grid
- 10343 - Overcoming Challenges and Progressing Electrical Substations toward Digital Transformation
- 10362 - The 36 kV voltage level – a new standard solution for grid integration of renewable energy sources
- 10582 - Monitoring System of Earth Loop Impedance to Verify Step and Touch Voltages
- 10684 - European Experience of Developing from Asset Reliability Information to Risk Method for Optimal Investment on Substation Assets
- 10716 - A system risk approach for management and optimization of critical spare parts
- 10737 - GIS for offshore and floating applications
- 10738 - 420 kV SF6-free High Voltage Gas Insulated Switchgear Design, Type Tests and Product Footprint
- 10739 - New Standards and Solutions for Service Continuity of HV GIS
- 10740 - Retrofill for 420 kV Gas-Insulated Lines: Technical Concept and Return of Experience
- 10741 - Implementation of the new IEC and CIGRE requirements on service continuity to high voltage gas insulated switchgears
- 10769 - Case Studies - GEOBIM Substation and Power Generation Reality Capture for Digital Twin purposes
- 10771 - Digital twins applied for intelligent analysis and real-time monitoring of circuit breakers in electrical power substations
- 10781 - First Step toward Carbon Neutrality using BESS Project in South Africa
- 10795 - New Competencies and diagnostic Methods needed for the Application of Composite Insulators in Substations
- 10796 - The Impact of Digital Transformation on the Asset Management System
- 10903 - The role of increased standardisation in the delivery of substation infrastructure to enable a low carbon future in Ireland
- 10960 - Experiences with commissioning of a 132 kV GIS SF6-free digital substation
- 11029 - Commissioning and operational experience with the first switchgear of its kind to integrate digital and greenhouse gas-free components for power transmission
- 11036 - Experience with HVDC GIS application during commissioning and early operation phase
- 11087 - Impact on Engineering and Lifetime Management of High Voltage Outdoor GIS
- 11088 - Management experience of condition-monitoring system and development of new IoT devices
- 11089 - Management of SF6 gas leakage and repair technology in gas insulated equipment
- 11090 - Study on Advanced Maintenance Strategies and Asset Management for Substation Equipment in Japan
- 11092 - Sustainable improvement on substation resilience and reliability by using eco-friendly equipment and remote maintenance systems
- 11093 - Verification of Substation Condition Monitoring by Linking IEDs with Existing Substation Equipment
- 11097 - Retrofit GIS Service Solution for extended Lifetime Maintenance
- 11143 - New test and commissioning tools and concepts for Low Power Instrument Transformers
- 11147 - Offshore floating HVAC and HVDC substations – Experiences in design of selected primary equipment
- 11159 - Operational experience with dynamic current rating of busbar systems in 220-kV-substations
- 11201 - SF6 Insulated Substations: Challenges and Lessons Learned for Improving ISA Group Operational Reliability and Sustainability.
- 11202 - Sustainable Urban Electrical Substations: an Integral View for a Sustainable Transformation of the Energy Sector
- 11210 - Methodology for the Condition Analysis of High Voltage Capacitor Banks (Proposal and application case)
- 11306 - Return of experience on gas handling with C4-FN mixtures for high-voltage equipment
- 11334 - Sensitivity Study and Operational PD Monitoring Experiences of SF6-free GIS
- 11435 - Autonomous Inspection Robots for use in HVDC Converter Halls
- 11444 - Compact photoacoustic sensor system for the continuous monitoring of SO2 and SF6 percentage in gas-insulated switchgears
- 11475 - Continuous Improvement of Arc Flash Assessment for Work Place Safety
- 11499 - Development of Asset Risk Mapping to Support Asset Management Decision Making in an Integrated Electricity Utility
- 11537 - Optimization of overall HV cable length in hybrid transmission technologies used for evacuation of power from off-shore wind parks/Solar parks by implementation of compact transition station.
- 11538 - Challenges And Lessons Learnt Through Failure Experience And Initiatives To Strengthen Resilience Of The Gas Insulated Switchgear
- 11547 - Controlled Switching Of Coupled Power Transformers Based On Residual Flux Estimation Including State Of Art Digital Monitoring Technique – Field Experiences
- 11552 - EV Changing Infrastructure Design Challenges And Solutions – Case Study
- 11555 - Design Philosophy of Extension bays for EHV Gas Insulated Switchgear
- 11556 - Challenges Of Managing Assets: Initiatives To Strengthen Resilience, Reliability And Security, Best Practice And End-Of-Life Management Considering Sustainability Aspects.
- 11560 - Service Continuity Criteria for Gas Insulated Switchgear (GIS) - Utility Experience in Green Field and Brown Field GIS Substations
- 11598 - Challenges And Precautions During Design And Engineering Of Gas Insulated Switchgear (GIS) Substation Of Hydro Projects
- 11604 - Novel Solution for Converting Existing 400kV I-Type One & a Half Breaker Scheme to D-Type for Evacuating Double Circuit Lines in Same Direction Using 3D Modelling
- 11605 - Optimization Approach for the Layout design of 400/220kV Gas insulated Switchgear (GIS) Substations
- 11646 - Development of DC 320kV, 525kV GIS Cable terminations
- 11725 - Gas Insulated Substation (GIS) Overhaul Prioritizing Index Calculation a Case Study East Java and Bali Population
- 11800 - Digital Technology Breakthrough Experience in Increasing Grid Operational Efficiency and Productivity
- 11801 - Spearheading Asean Utility Role in Sustaining Green Environment by Intensifying Effort to Reduce SF6 Leakage in GIS Equipment – User Experience Sharing
- 11816 - Design and Considerations for Station Service Voltage Transformer (SSVT) to Provide Low-Voltage Supply in EGAT’s Substation
- 11824 - Amesbury #5 Substation Emergency Power Transformer Relocation
- 11893 - Substation Design Improvement Considering Actual Accident Due to Direct Multiple Lightnings
Additional informations
Publication type | Session Materials |
---|---|
Reference | SESSION_2024_B3 |
Publication year | |
Publisher | CIGRE |
Study committees |
|
Price for non member | 150 € |
Price for member | 100 € |