Summary
Measuring partial discharge on transformers and rotating machines requires knowledge of the frequency characteristics of the the object impedance. This allows assessing capacitive or transmission line behavior and localizing resonances. Impedance measurement is a helpful tool to correctly select the coupling capacitor and measuring impedance for optimal sensitivity. In this paper, a method of impedance measurement is presented based on the same frequency response Analysis (FRA) equipment used for transformers. The typical decrease with frequency of the equivalent capacitance of tranfsformers and the Transmission line behavior of rotating machines are investigated both with simulations and measurements. The impedance measurement gives insight to the electrical behavior of the test object, serves to find resonances and flat sections in the spectrum and therefore provides valuable Information for correct PD measurement.
Additional informations
Publication type | ISH Collection |
---|---|
Reference | ISH2015_412 |
Publication year | |
Publisher | ISH |
File size | 1 MB |
Price for non member | Free |
Price for member | Free |
Authors
Wattanawongpitak Sarawut, Ruankon Sayan, Suwanasri Cattareeya, Lipirodjanapong Sumate