Summary

  • Discussion of methods of analysis and modelling related to the interaction between HVDC converter stations and their controls with their associated AC systems
  • Discussion of methods of application of static VAR compensators to meet stability and voltage requirements of AC/DC transmission systems
  • Comparison of the techniques, economics and reliability of AC and DC transmission systems

The list of papers is available, please contact the Publications Team to select the papers you are interested in

1. SYSTEM REPRESENTATION TECHNIQUES

  • 100-00 Special Report 
  • 100-01 New development of HVDC digital simulation
  • 100-02 Modelling of an HVDC system for digital simulation of AC/DC transmission interactions
  • 100-03 Modelling a double circuit line transmitting AC and DC on the same tower
  • 100-04 Evaluation of developments in DC models for AC/DC transient stability programs

2. ANALYSIS OF /NTERCONNECTED AC/DC SYSTEMS

  • 200-00 Special Report
  • 200-01 Special aspects of integrating the Ouernrohr HVDC  back-to-back link into the UCPTE and CMEA networks
  • 200-02 Interactions between the ltaipu HVDC transmission system and the 50 Hz/60 Hz systems : analysis, modelling and operational planning
  • 200-03 HVDC power transfer capability associated with AC receiving system's stability and means of improving integrated system performance
  • 200-04 Planification d'un grand réseau de transport - Interactions entre une ligne à courant continu et les lignes à courant alternatif
  • 200-05 Comparative performance of an HVDC transmission system with DC breakers for clearing DC line faults
  • 200-06 Kansai 500 kV system harmonies : present status and future AC/DC system design
  • 200-07 Stabilization of HVDC system operation, under the unbalanced AC system voltage
  • 200-08 Analysis of dynamic behaviors of HVDC system considering AC voltage wave distortion
  • 200-09 Itaipu HVDC transmission system-dynamic performance of bipole 1
  • 200-10 Effects of the HVDC transmission on the AC line protections
  • 200-11 Controllable AC/DC dynamics in the Western U.S. power system
  • 200-12 Control of temporary overvoltages in AC/DC systems by metaloxide overvoltage limiter
  • 200-13 The behaviour of the 2 000 MW DC link with England during faults affecting the French power system : on-site tests
  • 200-14 Impact of system parameters on non characteristic harmonies of HVDC transmission
  • 200-15 Characterization and control of harmonie overvoltages at HVDC stations
  • 200-16 The generation measurement and suppression of telephone interference on the Cahora Bassa HVDC transmission system
  • 200-17 Performances of AC/DC systems in case of parallel and series tapping feeding a very weak AC network
  • 200-18 Analysis of AC/DC system interactions using a large scale transient stability program
  • 200-19 DC alternative for the transmission from the Amazon basin : dynamic performance of the AC/DC Brazilian interconnected system during severe transients
  • 200-20 Interaction between DC and AC systems
  • 200-21 AC/DC interactions on the 2 000 MW UK-France (Cross Channel) HVDC link

3. CONTROL OF AC/DC CONVERTERS

  • 300-00 Special Report
  • 300-01 Application of advanced HVDC modulation techniques to large scale power systems 
  • 300-02 Measurement based optimal control of high voltage AC/DC systems
  • 300-03 The study of a control and protection system for nuclear power plants - The radial HVDC transmission system
  • 300-04 Aspects of the Uruguaiana frequency converter station system
  • 300-05 Stability improvement for AC/DC interconnected system by power system stabilizing method
  • 300-06 Advanced control methods and application for multi-terminal HVDC systems
  • 300-07 Control and protection aspects of multi-terminal DC systems 
  • 300-08 HVDC back-to-back inerties on weak AC systems - Second harmonie problems - Analyses and solutions
  • 300-09 Quebec-New England phase Il - HVDC transmission system part Il - Multiterminal control strategy for dynamic performance
  • 300-10 Quebec-New England phase Il - HVDC transmission system part 1 - Steady state multiterminal control strategy
  • 300-11 The application of minimal time control theory in DC modulation - Research of the Three-Gorges Hydro Project
  • 300-12 Vindhyachal HVDC project : HVDC control design for improved system stability 
  • 300-13 Dynamic performance study for the Vindhyachal back-to-back HVDC station
  • 300-14 Design of a modulation controller for stabilization of parai lei AC lines in the Rihand-Delhi HVDC transmission
  • 300-15 Automatic control of power systems with HVDC and HVAC transmission lines

4. CONTROL OF REACTIVE COMPENSATION IN AC/DC NETWORKS

  • 400-00 Special Report
  • 400-01 lmprovement of DC/weak AC system interactions with a new conversion and control scheme
  • 400-02 Application of static var compensator for AC/DC interconnected power system
  • 400-03 Application of static var compensators to a long-distance transmission system supplying static frequency converters
  • 400-04 Reactive power control in AC/DC systems by HVDC converter station 
  • 400-05 Reactive and DC power dispatch to minimize transmission lasses of an integrated AC/DC power system
  • 400-06 The use of thyristor-controlled static var compensators at HVDC converter stations
  • 400-07 An optimal reactive power controller for stringent var exchange requirement in an AC/DC network : design aspects
  • 400-08 Design and operation of the AC voltage and reactive power controllers for the Miles City and New England HVDC projects

5. COMPARISON OF AC AND DC TRANSMISSION

  • 500-00 Special Report
  • 500-01 Comparison of costs and benefits for DC and AC transmission
  • 500-02 Comparison of AC and DC underground and submarine cable transmission systems
  • 500-03 Corona and field effects of AC and DC transmission lines in close proximity
  • 500-04 Reliability assessment of the IPP power delivery system 
  • 500-05 Comparisons between HVAC and HVDC systems in China
  • 500-06 Factors affecting AC and DC transmission system reliability and methods for assessing their influence
  • 500-07 Comparison of AC and DC transmission alternatives for the new East-West interconnection in Ontario
  • 500-08 Trends in techno-economic choice of HVDC projects in lndia

Additional informations

Publication type Symposia
Reference SYMP_BOS_1987
Publication year
Publisher CIGRE
Price for non member 80 €
Price for member Free
BOSTON: AC/DC Transmission. Interactions and Comparisons
BOSTON: AC/DC Transmission. Interactions and Comparisons