Summary

The limits of current technology are frequently set by the availability or otherwise of suitable materials. Materials may be used for constructional purposes or in more active roles as a consequence of their special electrical, magnetic, insulating, dielectric or other physical properties. Concerns are new or improved materials and their applications in electrical apparatus. Solids, liquids or gases with novel properties that can be utilised in electrotechnology. Information on the performance of these materials.

Contact us to select your documents from the list of papers

1 - LATEST  DEVELOPM ENTS  OF  MATERIALS  FOR  SPECIAL PURPOSES

Section 1 - Materials  for very low  (cryogenic) temperatures

  • 100-0 J.L.  SABRIE.  Rapport  Spécial  /  Special  Report
  • 100-01 J. GERHOLD (Austria). Dielectric strength of gaseous and liquid insulants at low temperatures

    100-02 H. KÔFLER. E. TELSER (Austria). Wire insulation applicable in  cryogenic seNice

    100-03 B.  DALLE.    A.   ANSART.   HOANG   GIA   KY. P. DU BOTS (France). Caractéristiques des brins supraconducteu rs utilisables  en  régime alternatif

    100-04 J.C.   BOBO.  J.   POITEVIN.   H. NITHART'(France). Tenue diélectrique  des isolants à 4.2   K

  • 100-05 IA GLEBOV. YA.B. DANILEVICH. L.T. PONOMA­ REV.  O.S.  BOGOYAVLENSKY  (USSR).  The  bon­ding material for superconducting magnetic sys­ tems
  • 100-06 M.   KAHLE.  P.  FROSCH   (German   Dem.   Rep). Application problems of LN2/paper-insulation

    100-07 L. INTICHAR. HW.  N EUMULLER. T.S. KULIG (Fed. Rep. of Germany). Requirements for supercon­ ductors to be used in turbogenerator field win­ dings

    100-08 H. KRAU TH (Fed. Rep of Germany). Multifilamen­ tary  NbTi  and  Nb3Sn  suriP.rconductors  for pulse magnets  and  electrical machines

  • 100-09 P. KOMAREK A. NYILAS (Fed Rep of Germany), characterization of super conductors and insulating materials at cryogenic temperatures for use in electrical engineering 

Section 2 - Special  means  for  the  transfer  of  information  from  high  voltage  to  ground

  • 200-0 P. PIFFARETTI. Rapport Spécial / Special Report
  • 200-1 A.A.  MENEZEZ  JR..  E.M.  COSTA.  J.I.    SILVA FILHO. G.L. FEITOSA. (Brazil). Real time monito­ ring system for surface temperatures of overhead conductors
  • 200-2 M.P. GREAVES. J.S. McCORMACK. M.D.  ROWE. R.M. BOOTH.  B.J.BRENT (United Kingdom). The development and tesî of an optical fibre tempera­ ture senso r for use at high voltage in turbine generators

    200-3 V.M. KOPILOV. I.T. OFCHINNIKOV.  S.G.  SARIN E.V. YANSHIN (USSR) New electro-optical measuring system for insulation quality contrai under the high voltage stresses

Section 3 - Conducting materia/s and magnetic core materials

  • 300-0 D.J. ALLAN.  Rapport Spécial /  Special  Report
  • 300-1 M.IEDA.  T.  MIZUTANI.  Y.  SUZUOKI.  A. OHKI (Japan). Conduction and degradation mecha­ nisms of zinc oxide  varistors
  • 300-2 A. KOZLOWSKA (Polànd}. Application of a vec­ tormeter to investigate the cores wound with amorphous ribbon
  • 300-3 J. GALAND.  B. LELIEVRE.  J.C.  NICOUD (France).Conducteurs en aluminium et alliages d'alumi­ nium  : nouveaux  développements
  • 300-4 P.   SCHÔNHUBER.  H.  PFÜTZNER  (Austria).   C.BENGTSSON (Sweden). On design problems of transformer cores resulting from the application  of high grade stress coated  SiFe-sheets
  • 300-5 R.  SCHULZ.   N.  ALEXANDROV.   R.  ROBERGE(Canada). Distribution transformers materials limi­ tations applicabi lity  of  amorphous magnetic core materials
  • 300-6 O.P. CHABRA (lndia). Magnetic slot wedges for electrical machines

2.LATEST DEVELOPMENTS AND IMPROVEM ENTS  OF INSULATING MATERIALS

Section 4 - Gaz insulated systems

  • 400-0 G.  LUXA.  Rapport  Spécial  /  Specia/  Report
  • 400-1 J. MUDRA (Czechoslovakia.) Influence of corona· discharge action on  electro-insulating propertiesof the SF6 + N2 gas  mixture
  • 400-2 R. SCHMID, W. ZAENGL (Switzerland). Investiga­ tions to the use of the insulation gas -mixture 50 % 1.2-C2Cl2F4 / 50 % SF6 in metal -enclosed me ­ dium-voltage   switchgear
  • 400-3 M. ZWICKY. W ZAENGL (Switz erland), Investiga­ tions related to the dielectric  strength  of  SF6  in the frequency range of 30-200 Hz with respect to on-site  testing  of GIS
  • 400-4 J.M. BRAUN, LA   GONZALEZ. FY   CHU (Canada).A model of moisture ingress and  distributi on  in gas  insulated switchgear
  • 400-5 G.C.  STONE,  S.A.  BOGGS,  J.M.  BRAUN ,   M.KURTZ (Canada), Reliability of epoxy components in  high  voltage switchgear
  • 400-6 H. LATOUR-SLOWIKOWSKA. S.  JANKOW ICZ, S.SLOWIKOWSKI. J.LAMPE (Poland), Sorne re­ marks on extrapolation of laboratory  results  of SF6 by-produc ts analysis to the application fo r the surveillan ce  of GCB
  • 400-7 F.  HAMMER,  J.  W ELTGEN  (Fed.  Rep . of Ger­many), SF6-gas impregnated ail film dielectric with folded foil-edges for high voltage capacitors

Section 5 - Liquids and liquid-insulated system 

  • 500-0 A.H. COOKSON, Rapport Spécial / Special neport
  • 500-1 S.   SANKARA LINGAM, K.R.   KRISHNASWAMY,(lndia), New dielectric liquids from vegetable origin - A feasibility study on lndian rape seed oil

  • 500-2 V.N.  NAGARAJA  RAO ,  K.  KUMAR.  T.S. RAMU (lndia). On the assessment of insulating oils based on their gassing tendencies
  • 500-3 A.S. PILLAI, DA DOSHI (lndia), Impulse break­ down characteristics of transformer oils used in lndia
  • 500-4 E.D. SENKEVITCH, V.G. ARAKELIAN, TV GLA­ SUNOVA. VA   LIPSHTEIN, T.I. MOROZOVA. N.M PANOVA (USSR), New synthe tic liquids for trans­formers

    500-5 H.P. MOSER, V. DAHINDEN, E. SCHNEIDER. P. BRUPBACHER .  H.HUMMEL,  H.  BRECHNA,   F.ZÜGER (Switzerland), New results on agïng or aramid and cellulose pressboard under selective conditions

    500-6 A.  MARINHO  Jr ,  E.G.  SAMPAIO.  M.M.   MON­TEIRO (Brazil),  Castor  oil  as an insulating  liquid

    500-7 K.M .KAMA TH. T.S.R. MURTHY (lndia), Accelerated ageing studies on paraffinic and naphthenic based insulating oils using different inhibitors and passivators

    500-8 Th. FACKLAM, D. KÔNIG . G. W IEGNER (Fed. Rep.of Germany ), The fluocarbon C2 Cl3 F3 as a boiling co.oling and insulation medium in traction inverters

    500-9 

  • W   BREUER,   G.   HEGEMANN   (Fed.   Rep . of Germany), Behaviour of on-load tap changers in MIDEL 7131. A PCB-alte rnative for transformers

Section 6 - Solid insulating materials 

6.1 : Latest developments 

  • 610-00 H.G. TEMPELAAR. Rapport Spéci al / Specia / Report
  • 610-1 K.  PLUESS. K. BRAN DENBERGER (Switzerland). A new cost- effective VPI-MI CA paper tape for global  impregnation
  • 610-2 K. BRANDENBERGER (Switzerl and ). An alysis of a Roebel bar insulation system after 14 years ser­ vice life in  a generator
  • 610-3 D.  KÔN IG,  H.J.  HELLER. B.  BAYER,  P. WEST­BROCK (Fed. Rep. of Germ any), Polyurethane hard foam insulation. Sorne fundamentals and relevant applica tions in high voltag e switchgear technology
  • 610-4 J. HEIGHES, B. RIC HARD SON (United Kin gdom).Designing  with modern polymerics
  • 610-5 H.K. PAL. P.V BHAT (lndia). Slot discharge activity in high voltage machines using thermo setting insulation system

    610-6 H.K. PAL. P.V. BHAT (lndia), Thermal endurance profile  of  an  insulation  system

    610-7 G.  DE TOURRE,IL   J . LANTEIGNE.  P.  NGUYEN­DUY. P. BOURD ON (Canada). Performance of composite dielectric materials under high mecha­ nical  stress

    610-8 M.  KAHLE. W.  ROTH,  K. HANELLA. P.  FROSCH(German Dem. Rep.), PIO - A thermostable insula­ ting  material  system for high reaction technology

    610-9 M. PARIS. N. RECROSIO (France). Caractérisation des isolants solides vis-à-vis de leur comporte­ ment  au feu

    610-10 J.J. SMIT. R. ROSS (The Netherlands). Manufactu ­ ring influences on the HV-AC endurance of epoxy-resin  insulation

    610-11 G. LIPTAK. R. SCHULER (Switz erland). State of development of turn insulation for stator windings with form wound coils for high voltage rotating machines

    610-12 H. GSODAM. G.PRAXL. W. SCHOBEL  B. ZIMICS(Austria). Mechanism of the thermo-electrical long-tim e breakdown in epoxy-mica-insulation systems

6.2 : Electrical  treeing and XLPE materials

  • 620-0 M. SAURE. Rappo rt Spécial / Special Report
  • 620-1 T.F.E. WALLA (Austria). About  possible influences of  the po lymer  structure  on water-tree  growth

    620-2 W.  WEISSENBERG.  P.  KÜLLIG. W.  MOSCH. M.EBERHARDT (Germ an Dem. Rep.), The influence of thermo-oxidated and deteriorated particles of polyethylene as macroscopic impe rfection and the lifetime curve at AC stress in PE/XLPE insu­ lated cables

    620-3 Al LING TAN. J.H. MASON (Brazil), The resistance of a polymer concrete to weathering and tracking

    620-4 J.C. FILIPPIN I, Y POGGI. V. RAHARIMALALA (France).  J.J.   DE  BELLET.  G.  M ATEY  (Switz er­

  • land), A review of investigations on the relationship between mechanical  propert ies. polymer morphology and water tree growth in different polymers
  • 620-5 M. BEYER. F. M ERSCHEL (Fed. Rep. of Germany),Generation and proving of water treeing in EPR-spec imens under laboratory conditions
  • 620-6 P FISCHER. E.F. PESCHKE. R.G. SCHROTH (Fed.Rep . of Germany), A.A. FARKAS (Sweden). Deve­ lopment and reali zation of watertree retardant XLPE compounds  and cables

    620-7 O. BÔTIGER.  W GÔLZ.  M . SAURE (Fed. Rep  of Germany). Water tree theory and progress in XLPE-materials

    620-8 K. MARTON (Czechoslovakia). Contribution of electric forces to the development of elect ric  treeing  etfects

    620-9 E.F STENNIS, A.M.F.J ud. LAAR (netherlands) ageing of extruded cables in water

    620-10 M.SAURE, W. KALKNER, on water tree testing of materials status report of cigre TF 15.06.0

3. LATEST DEVELOPMENTS OF METHODS FOR THE SURVEILLANCE OF ELECTRICAL APPARATUS IN HIGH VOLTAGE POWER NETWORKS 

Section 7 - Partial discharge measurements 

  • 700-0 F.H. KREUGER,  Rapport Special /  Special  Report
  • 700-1 W.S. ZAENGL, A. KLAUS (Switzerland). On-site surveillance of potential transformers by means of PD-measurements

    700-2 J. ZALEWSKI, J. SKUBIS (Poland). The evaluation of partial discharges appearing in power electrical equipment  by  the  accoust ic  emission method

    700-3 E. BINDER (Austria), Techniques of partial di­ scharge measurements for stator windings of generators

  • 700-4 S.A. BOGGS. D.D. PECENA,  S. RIZZETTO,  G.C.STONE (Canada), Limits to partial discharge detection - Effects of sample and defect geome­ try
  • 700-5 F.H.  KREUGER,  W.A.  SONNEV ELD,  R.J. VANAALST (The Netherlands). Three phase detection

    700-6 DA HILDER (United Kingdom) . Partial discharge measurement and other insulation monitoring techniques  in  harsh  electrical environments

    700-7 M.BURGMANN G. ISSEL R. TZSCHEUTSCHLER (German Dem.rep) Partial discharges in oil­ paper  insulation  of  testing  transformers

Section 8 - Dissolved gas analysis and other methods

8.1 : Dissolved gas analysis 

  • 810-0 H. FOSCHUM . Rapport  Spécial  /  Special Report
  • 810-1 G. MORAW (Austria). ExperienGe wit h dissolved gas analysis for high power converter transfor­mers

    810-2 O. KERENYI. Z. RABEL (Hungar,y) A simplified method of dissolved gas analysis for the  surveillance of voltage transformers in high voltage power networks

    810-3 A. WICHMANN.  Ch.  LOHSE  (Fed.  Rep . of  Ger­many). Possibilities and limits of local overheating detection in generators by dissolved gas analysis

    810-4 J. BREDE. H.J. RINDF LEISCH. J. SCHM IDT (Ger­man Dem. Rep.). Combined  applicat ion  of  radiation chemical and gas analytical methods on transformer oil

8.2 : Other methods 

  • 820-0 W   LAMPE. Rappo rt  Spécial /  Special  Report
  • 820-1 M. KHALIFA. S.E.D. HABIB. A. EL-MO RSHEDY. O.GOUDA (Egypt) . An intelligent monitor for exter­ nal insulation  of high voltage  power networks

    820-2 J.  KEDZIA.  E.  BRZOSTEK  (Poland, )Electrostatic properties of transformer oil as a measure of its aging

  • 820-3 J.L. KIRTLEY JR.. J.C. LAVALLE. D.J.  McCARTHY (United States). Acoustic monitoring of transfor­ mer structures
  • 820-4 M. KAHLE. E. NEUD ERT. K. WA LLI, R. EITNER. D.NEITZ (German Dem. Rep. ), A diagnost ic system for ageing studies on base of acoust ical em ission analysis
  • 820-5 R.  GOFFAUX  (Belgique).   Bases  théoriques  de l'instrumentation TESTACEC dest inée au diagnos­tic de l'isolation HT de machines à courant alternatif
  • 820-6 M.C.  ZARETSKY. J.R.  MELCHER.  C.M. COOKE(United States). On line monitoring of moisture in transformer oil using microdielectrometry

4.QUALITY  ASSURANCE  AND  SURVEILLANCE  OF ELECTRIC AL APPARATUS IN  HIGH VOLTAGE SYSTEMS

Section 9 - Quality assurance 

  • 900-0 G.  ST-ONGE.  Rapport  Spécial /  Specia/ Report
  • 900-1 G. THEIL (Austria), Indices and confidence limits for the reliabi lity evaluation of high voltage trans­ mission system  components

    900-2 M.B. SRIN IVAS. T.S. RAMU (lndia). Monte-Carlo approach to ageing data acquisition and ·analysis of  apparatus insulation

    900-3 H.T TEICHMANN (IEC - Switzerland). International standardization  in  the  field  of  liquid dielectrics

    900-4 N.P.  ALEKSANDR OVA,  A.K.  MANN  (USSR). lnsulation ageing regularities and service life fore­ casts  for  power capacitors

    900-5  C. -LAMARRE. J.P. CRINE. H . ST-ONGE (Canada). Antioxidant functionality in liquid and solid dielec­ tric materials

    900-6 S. HOFER (Austria). Ouality assuranc e of power transformers

    900-7 P.G AGASHE and VIMALA SITARAMAN (India) Thermo analytical techniques in evaluation of insulating materials

Section 10 - Surveillance

10.1 : Surveillance of network voltage 

  • 1010-00 Special Report 
  • 1010-01.E.  JAMES.  F.E.  TRICK.  B.T.  PHUNG.  PAWHITE (Australia). A microprocessor based system for the  electrical  location of partial discharges : example of application to a large transformer winding
  • 1010-02  F.  REISINGER.  M .  MUHR.  H.  SCHENNER (Aus­tria). A. DIESSNER (Fed. Rep. of Germany ), Field measuremerits of fast transient voltages in the 420 kV-GIS Wien Sued
  • 1010-03  N. FUJIMOTO.  S.A.  BOGGS.  G.C.  STONE (Ca­nada). Mechanisms and analysis of short rise­ time  GIS transients

    1010-04 J. ROGUIN (France). Determination des contrain­tes  transitoires  dans  un  poste THT

    1010-05 E. GOCKENBACH (Switzerland). A new measu­ring device for transient overvoltages in trans­mission  lines

    1010-06 G. ALDROVAND I. C. CARUBEL LI. G. FURIOLI (ltaly).  Z.  AQUINO.   U    GAVIDIA.   M.  MILLAN (Venezuela). Measurements of switching tran­sients during the field tests performed for the commissioning of the EDELCA 765 kV  system

10.2 : Surveillance of high voltage apparatus 

  • 1020-00 C.DUBANTON.  Rapport Spécial. Special Report
  • 1020-01 J. SAIY (Iran). Multiple explosions of current transform ers due to poor quality of materials used and inadequate acceptance  tests
  • 1020-02 E.LEMKE. R. RÔDING . W. WEISSENBERG (Ger­man Dem. Rep .), On-site testing of extruded power cables by PD m easurements at SI volta­ ges
  • 1020-03 A.WICHM ANN.  P. GRUENEW ALD.  J. WEIDNER(Fed. Rep. of Germany). Early fault detection in electrical  machines  by  on-line  RF monitoring
  • 1020-04  A.MORETII.  C.   NADALI.  E.   SERENA  (ltaly).Evaluation of insulation condition in high voltage current  transformers
  • 1020-05 A.KELEN (Sweden). Diagnostics of HV machine insulation From inspection to continuous moni­toring
  • 1020-06 R. M AGU.  REANU . D. STANCIU. O. MUSTATA. C.MARIN (Ruman ia). M onitoring and diagnosis of large  power electrical  transformers         '

    1020-07 E.KEIL (A ustria ). AC investigations of the insulation  of  HV  equipment  in  theory  and practice

    1020-08 M.DOMUN.G. CORNFIELD. A. HADFIELD(United  Kingdom)  Prediction  of  remaining  lives of  132 kV grid transformers

Additional informations

Publication type Symposia
Reference SYMP_VIE_1987
Publication year 1987
Publisher CIGRE
Price for non member 80 €
Price for member Free
VIENNE: New and improved materials for electrotechnology